Process Hydraulics, Part 10: Gas–Liquid and Three-Phase Separator Sizing, Souders–Brown and Internals
Separator zones, gravity settling laws, Souders–Brown K, sizing vertical and horizontal two-phase separators with and without mist eliminators, inlet devices and mist extractors, nozzle momentum limits, three-phase separators with weir or boot, and the governing-diameter method. A droplet-settling animation and a three-phase separator simulator.
SM
Sumit Mathur
22 min read
Almost every process has a place where a mixed stream must be split into its phases: a compressor knock-out drum, a flash drum, a reflux accumulator, an inlet separator, a flare knock-out drum. The tool is the separator, and the principle is gravity: give the phases enough quiet time and space to part.
This is Part 10 of 10, the last in the series. Part 9 covered vessel basics and surge drums.
1. What a separator is, and its nomenclature
In oil-field terminology a separator is a pressure vessel that splits well fluids into gas, oil and water. The same equipment is called, depending on its duty, a separator, stage separator, knock-out (KO) drum, flash vessel, scrubber or gas filter.
2. Why gravity separation works, and where it stops
Separation reasons: remove unwanted fluids, divide a desired product, divide phases for further processing, protect liquid- or vapour-handling equipment (compressors, pumps).
Two basic design principles: low vapour velocity and long liquid residence time. The fluids must be immiscible and of different density; the closer the densities, the harder the separation; and no separation is complete, so the required degree of removal must be stated.
The things you must define before starting: maximum liquid rate, gas rate, operating temperature and pressure, densities of both phases, the required liquid retention time, solids, foaming tendency, and whether an aqueous and an organic phase are present.
The four zones
Almost every separator has four zones, whether or not they are visible:
Primary separation: where the stream enters; the inlet device removes the bulk of the liquid and kills the momentum.
Secondary (gravity) separation: the gas is slowed so that smaller droplets can settle.
Coalescing / mist extraction: a mesh pad or vane pack catches the smallest droplets.
Liquid collection (sump): retains liquid long enough for any dissolved or entrained gas to break out and for level control and surge.
3. Gravity settling laws
A droplet in a gas stream feels three forces: gravity down, buoyancy up, and drag opposing its motion relative to the gas. At terminal velocity the forces balance:
vt=3ρ
The drag coefficient CD depends on the particle Reynolds number Rep=ρVvtd/:
Regime
Re_p
Drag law
Stokes (viscous)
< 2
CD=24/Rep, giving
Because CD depends on vt, the calculation is iterative (the widget below solves it with a blended drag law). Larger droplets and bigger density differences settle faster; thicker (denser) gas, higher gas viscosity, and smaller droplets settle slower.
4. Sizing a vertical two-phase separator
In a vertical vessel the gas rises, the droplets fall: the gas velocity must be below the droplet terminal velocity.
Method A: Souders–Brown K
The design gas velocity is a fraction of the terminal velocity of the design droplet, packaged as:
Vmax=K
K (in m/s) depends on the service and on whether a mist eliminator is present:
Internal
Typical K, m/s
No mist extractor (vertical vapour–liquid separator)
Always follow the project standard; K is a calibrated number that already includes a safety margin on droplet size.
With a mist eliminator, round the calculated diameter up to the next 150 mm (6 in) so a support ring can be fitted.
Method B: from a design droplet size
Choose the smallest droplet that must be removed (for example 150 µm), calculate its terminal velocity with the iterative drag, and keep the gas velocity below it (usually with a margin). This is the preferred approach where K values are not available or when the droplet distribution is known.
Try both views together. The droplets move with the gas; those whose settling speed exceeds the gas velocity fall out, those that don't are carried over. The table shows each size's settling velocity:
Animation – Droplets vs rising gas in a vertical separator
Droplet, µm
Settling v, m/s
Outcome
40
0.04
carried over
80
0.10
carried over
120
0.15
carried over
180
0.23
carried over
250
0.32
carried over
350
0.43
carried over
500
0.58
carried over
700
0.75
settles
Gas velocity
0.68 m/s
Souders–Brown limit
0.39 m/s
Utilisation
172 %
Cut size
605 µm
Minimum drum diameter for this internal: 1.97 m (round up to the next 150 mm when a mist-eliminator support ring is needed).
A droplet falls only if its terminal settling velocity beats the gas velocity. The Souders–Brown limit V = K√((ρL−ρV)/ρV) is the practical gas velocity ceiling for a given internal. Slow the gas (a wider drum, or lower flow) and ever-smaller droplets drop out; speed it up and they ride out with the gas.
Height of a vertical separator
From the bottom tangent line upward you need: space for the LLLL (and the boot or sump), the liquid hold-up between low and high levels (from residence time), a clearance between the high-high level and the inlet nozzle, the disengaging space above the inlet (to let liquid drop out of the gas before it reaches the demister), and the mist eliminator and its outlet nozzle at the top. Typical minimum distances (project spec governs): bottom of vessel to LLLL at least 150 mm (or 0.15 D); LLLL to the low alarm about 150 mm; from the high alarm to the inlet nozzle at least 0.3 D or 300 mm; from the inlet nozzle to the mist eliminator at least 0.45 D or 900 mm.
5. Residence time and the liquid section
Liquid volume is set by residence time, the same method as for a surge drum (Part 9). Typical retention times range from 2 minutes for some knock-out duties to 10 minutes or more for feed drums, with flare knock-out drums based on the worst credible liquid inflow. Check also that foaming or emulsion tendencies do not require extra time.
6. Internals
Inlet devices
An inlet device has three jobs: reduce the momentum of the entering stream, separate the bulk of the liquid efficiently, and avoid shattering droplets (which makes them harder to remove) and re-entrainment. The choices, from simplest to most capable: no device, a diverter plate, a half-pipe, a vane-type distributor (Schoepentoeter) and a cyclonic inlet.
Mist eliminators
Mist eliminators remove droplets the settling section has missed. Benefits: better separation, less loss of product, purer product, no contamination downstream.
Type
Characteristics
Vane pack
Inertial impaction; handles high gas velocities; does not drain liquid back into the rising gas; liquid routed to a downcomer; proprietary; higher cost; similar efficiency to mesh
Wire mesh
Coalesces liquid; high efficiency across a wide velocity range; very small droplets; low ΔP (about 25 mm water gauge, 1 in H₂O); low cost; easy to install; plugs with fouling or hydrates, so avoid in dirty or hydrate-forming service
Centrifugal elements
Inertial; also separate solids; proprietary; less maintenance than a filter but lower efficiency, higher ΔP, wear and plugging
Filters
High efficiency down to very small particles; need replacement or back-wash; high ΔP; highest operating cost
Electrostatic precipitators
Very small particles (< 3 µm) removed by charge; large and costly; electricity use
Use mesh for clean general service, vanes for dirty or high-velocity service, filters or coalescers for very fine aerosols.
Other internals
A vortex breaker over each liquid outlet (essential if a pump takes suction from the drum), baffles to break surges in a horizontal drum, and a weir or boot in a three-phase unit.
7. Nozzles
Inlet nozzle momentum ρv2: not more than about 1000 kg/(m·s²) with no inlet device, or 1500 with one.
Vapour outlet:ρv2 below about 3750 kg/(m·s²).
Liquid outlets: velocity not above 1 m/s, minimum 50 mm size, fitted with vortex breakers.
Manways 450–600 mm; vents and drains per Part 9.
Relief connections follow API 520/521; connect to the vapour space upstream of any demister.
8. Three-phase separators
A three-phase separator splits gas, light liquid (oil) and heavy liquid (water). They can be vertical or horizontal; horizontal is far more common for appreciable liquid because it gives more interface area.
Two ways to hold the water layer:
Weir: an internal plate holds the oil level above the weir crest; oil spills over into a separate oil chamber; water is drawn off below the interface.
Boot: a small vertical vessel at the bottom collects the heavy phase and carries its own level control.
Oil in the middle, a coalescing blanket or plates accelerates the growth of droplets and speeds up settling.
The sizing logic (horizontal, three-phase)
Residence timet (set by experience, difficulty of separation, consequences of loss of level, emulsion tendency, solids). The liquid volume is VL=(Qo+.
Normal liquid level: typically about 50–60 % of the area; minimum vapour space 20 % of the area (25 % of the diameter); minimum liquid level 25 % of the diameter.
Choose L/D between 1.5 and 6 (3 is most economical).
Check the settling of each phase pair in turn:
Gas bubbles (about 175 µm) out of the light liquid.
Heavy-liquid droplets (about 125 µm) out of the light liquid, settling through the oil layer in less time than the oil takes to cross the vessel.
Light-liquid droplets (about 250 µm) out of the gas.
The velocity through any coalescing blanket.
The governing diameter is the largest of all the diameters calculated from residence time and each of the separation checks. Compute the length from L/D.
Boot sizing
Minimum boot diameter 250 mm; maximum about one-third of the shell outside diameter; boot L/D between 2 and 5.
Residence time for a level-controlled boot: 5–10 minutes (hand-drained boots, for tiny volumes, are sized for hours).
Check three things: residence time, separation of the light phase from the heavy in the boot, and the process limit velocity of the heavy phase. The largest governs the boot diameter.
See how oil viscosity decides whether water has time to settle. Increase the oil viscosity until the check flips:
Animation – A horizontal three-phase separator: gas, oil and water
Liquid volume
21.3 m³
Vessel Ø × L
2.47 × 7.4 m
Water settles through oil
46 min
Oil residence
15 min
Water droplets need longer to settle than the oil spends in the vessel: increase residence time, heat the oil, or add a coalescer.
Total liquid residence time fixes the volume; the water fraction sets the oil/water interface. Water droplets must settle through the oil layer before the oil reaches its outlet, so viscous oil needs more time. Change the oil viscosity and watch the settling check flip.
9. A selection summary
Duty
Typical choice
Compressor suction KO drum
Vertical, wire mesh, low K, conservative
Flash drum after a letdown valve
Vertical with inlet diverter
Reflux accumulator (with water boot)
Horizontal, boot or weir for water
Natural gas–condensate
Horizontal or vertical, with mesh or vanes
High foam or heavy solids
Large, longer residence, no mesh
Fine mist < 10 µm
Coalescer or filter downstream
10. A final checklist
Properties at actual operating conditions, densities of both phases, viscosity.
Maximum, normal and minimum flows, and slugging tendency.
Gas velocity vs. Souders–Brown limit with the chosen internals.
Liquid volume for residence and surge; instrument set-points.
For three-phase: settling time of the heavy phase, boot or weir, interface control.
Series wrap-up
Across ten parts you have gone from Re and f (Part 1) through fittings (2), liquid (3), gas (4) and two-phase (5) line sizing; the circuit-wide hydraulic profile (6); centrifugal (7) and displacement (8) pumps; and the vessels that hold and separate the process fluids (9, 10). For related topics, see the heat-exchanger series (shell-and-tube design, reboilers and hydraulics) and the pressure-safety-valve article.
Further reading: GPSA Engineering Data Book, Crane Technical Paper 410, API RP 14E, API 520/521, ASME B31.3 and Section VIII, and Perry's Chemical Engineers' Handbook.