Separation ProcessesProcess SafetyPressure VesselSurge DrumLevel InstrumentationASME VIIIVessel SizingResidence TimeAnimatedHydraulics Series
Process Hydraulics, Part 9: Pressure Vessels, Level Instrumentation and Surge Drum Sizing
What a process engineer specifies for a pressure vessel, vessel types, heads, nozzles and supports, orientation selection, codes and standards, protection (level, pressure, temperature and relief), and how to size a surge drum from residence time. Two animations: level alarms and a drum sizer.
SM
Sumit Mathur
19 min read
A pressure vessel is a container designed to hold fluid at a pressure different from the atmosphere. Drums, columns, reactors, heat-exchanger shells, bullets and spheres are all pressure vessels. Whatever its job, from holding up liquid to separating phases to hosting a reaction, the vessel must be sized by the process engineer and protected by the instrument and relief systems.
This is Part 9 of 10. Part 8 covered pump selection. This part and Part 10 deal with vessels and separators.
Pressure vessels (as defined in API 510, containers designed to withstand internal or external pressure, imposed by an outside source or by heat) serve to:
Store and transmit liquids, vapours and gases under pressure.
Perform separation: gas from liquid, liquid from liquid, solids out.
Absorb variations in the incoming flow and provide a steady feed to downstream equipment (surge).
Host reactions, distillation, heat exchange and so on.
They appear in oil and gas, refining, chemicals, power, food and beverage, and pharmaceutical plants. Typical process names: compressor knock-out drums, flash drums, reflux accumulators, surge tanks, reactors, distillation columns and bullets.
2. Types of vessel
Type
Where it fits
Vertical
Small footprint; high gas-to-liquid ratio; mixing duties; easy solids removal; shell length-to-diameter up to about 5:1 for small drums, taller for columns
Horizontal
Large liquid volume or surge; two liquid phases; low gas-to-liquid ratio; cheaper supports
Spherical
Very high pressure storage; most even stress distribution; difficult fabrication; rarely used for separators
Special-purpose names (regeneration towers, reactors, absorption columns) describe the use, not a new geometry.
3. The main components
Shell: the pressure-containing body: cylindrical, spherical or conical. Thin shells (boilers, tanks) and thick shells (high-pressure cylinders) are designed differently.
Heads: hemispherical (strongest, thinnest), 2:1 semi-elliptical (the most common), torispherical (flanged and dished), conical, and flat. Hemispherical and 2:1 elliptical cover most designs.
Nozzles: cylindrical penetrations for process connections, instruments (level gauges, thermowells, pressure gauges), manways for access, and direct attachment of other equipment.
Supports: carry weight, wind and seismic load.
Saddle: horizontal vessels, normally two.
Legs: small vertical vessels, and spheres.
Lugs: bolted to structure, for small to medium vertical vessels.
Skirt: tall vertical vessels; consider dead weight, operating weight, wind/seismic loads and connected piping.
Support choice depends on orientation, size, volume and height.
4. The process engineer's responsibility
The vessel is mechanically designed by the vessel engineer or fabricator, but the process engineer specifies, on the process datasheet:
Design temperature and design pressure (including vacuum and the highest pressure the vessel can be exposed to, from the hydraulic analysis and relief cases)
Vessel size and orientation (diameter, tangent-to-tangent length, L/D)
The universal pressure-vessel design code is ASME Boiler and Pressure Vessel Code, Section VIII (Division 1 rules; Division 2 design-by-analysis). Others: EN 13445 (European, harmonised with the Pressure Equipment Directive), PD 5500 (formerly BS 5500, UK), AD-Merkblätter (Germany), CODAP (France), IS 2825 (India, unfired pressure vessels), API 510 (in-service inspection), EN 286 (simple pressure vessels such as air receivers) and many others. Use the one your client or jurisdiction specifies; the process engineer states the code on the datasheet.
6. Equipment protection
A vessel is protected from overfilling, overpressure and temperature excursions by instruments and relief devices:
PSVs connect to the vapour space above any contained liquid, or to piping from the vapour space. On a vessel with a demister (wire mesh or vane pack), connect the relief upstream of the demister, or upstream of any potential restriction. Sizing of relief valves is covered in the PSV article series.
Animate it. Create an imbalance between inflow and outflow and see how long the level set-points give an operator to react. Turn the level controller on and the drum rides through:
Animation – Drum levels, alarms and operator reaction time
Level
1.50 m
Imbalance
0 m³/h
Time to trip
balanced
Hold-up / surge time
8 / 8 min
Level set-points divide a drum into zones: normal, surge (between normal and high) and hold-up (between normal and low), with trips beyond. Create an imbalance between inflow and outflow, then watch how long the drum buys you before it trips. The simulation is sped up 150×.
Typical level set-point rules of thumb
(Project specifications always govern.)
Keep the bottom tangent to the lowest trip (LLLL) high enough for the outlet nozzle, vortex breaker and instrument tapping, at least 150 mm.
Separate adjacent set-points (LLLL, LLL, NLL, HLL, HHLL) by enough height for the instrument to discriminate and the operator to react; 150 mm or more is a common minimum between any two.
Keep the HHLL a safe distance below the inlet nozzle, and the vapour-space height above the HLL enough for the separation duty (typically 0.3 D or 300 mm minimum in a vertical separator).
Hold-up time is the time between normal and low-low level at the normal outflow. Surge time is the time between normal and high-high level at the normal inflow.
7. Choosing the orientation
Process condition
Preferred vessel
High vapour rate, low liquid rate, one liquid phase
Vertical (makes efficient use of the cross-section for the vapour)
Low vapour rate, high liquid rate, one liquid phase
Horizontal (vertical may be considered)
No vapour phase, two liquid phases
Horizontal
Needs solids removal, small plot
Vertical
Large surge volume
Horizontal
Side-by-side comparison: vertical vessels give less entrainment, better level control, easier solids removal, a small plot area and better surge control per height, but a larger diameter for a given gas rate and poorer three-phase performance. Horizontal vessels handle larger gas/liquid ratio, a smaller diameter for a given gas rate, cheaper supports, more liquid surface for separation, two liquid phases well and less foaming; but level control is harder, they take more plot space and are harder to clean. Spheres are compact and strong, but have limited surge and very difficult level control.
8. Surge drums
A surge drum absorbs variations in flow and provides a steady feed. It:
smooths upstream fluctuations so downstream units see a uniform feed,
gives the operator time to correct a problem,
may be a dedicated vessel or part of another (the bottom of a column, say),
protects pump suctions from loss of liquid and absorbs temporary slugs.
Typical uses: a drum between a distant tank farm and a process unit; a drum after a reciprocating pump; a feed drum ahead of a furnace or reactor; a reflux accumulator.
Sizing from residence time
Take the feed rateQL (m³/h).
Choose a residence timet from the guideline for the service (the liquid holding time between the two relevant levels).
Liquid hold-up volume: VL=QLt.
Choose the fraction of the vessel that is liquid-full at the operating level, F (often 50–80 %), and compute the vessel volume: VV=VL/F.
Select an L/D (2–5 for surge drums).
VV=4π, then round up (to the next 150 mm) and set .
Check the vapour space, the nozzle velocities, and whether the levels between alarms fit.
Example. Feed 20.4 m³/h; 30 minutes residence, 75 % full, L/D = 3. VL=10.2 m³, VV=13.6 m³, D=(4×13.6/(π×3))1/3=1.80 m, rounded to 1.8 m, L=5.4 m. Reproduce it, then try your own numbers:
Interactive – Size a feed surge drum from residence time
Liquid hold-up
10.2 m³
Vessel volume
13.6 m³
Diameter (calc → rounded)
1.79 → 1.80 m
Length
5.40 m
Residence time × flow gives the liquid volume you must hold. Dividing by the fraction of the vessel that is allowed to be full gives the vessel volume; choosing L/D then fixes the diameter (here rounded up to the next 150 mm) and length. The defaults reproduce the textbook example: 20.4 m³/h, 30 min, 75 % full, L/D = 3.
Typical residence times
These depend on the service and on the consequence of a loss of level downstream; use the client specification. Representative ranges: feed drums ahead of a furnace or reactor 5–10 minutes between normal and low level; fractionator or unit feed tanks 10 minutes; reflux accumulators 5–10 minutes; column bottoms 2–5 minutes; compressor knock-out drums for liquid hold-up 5–10 minutes; flare knock-out drums sized for the largest credible liquid inflow (20–30 minutes of retention); refrigeration feed tanks 2–5 minutes. Longer times add cost; shorter times add risk and operator workload.
9. General design considerations
Dished heads are usually ignored in the volume calculation for preliminary sizing (a small error on the safe side) unless the heads are large relative to the shell.
L/D between about 3 and 8 is acceptable for separators; 3 is the most economical for surge drums.
In a vertical vessel, the feed nozzle should be at least about 0.6 m above the bottom and 1.2 m below the top tangent (varies); in a horizontal vessel, about 250 mm above the bottom and 400 mm below the top.
In a horizontal three-phase vessel, the interface need not sit at the centreline.
Instruments: a temperature indicator at the outlet; a pressure gauge on every vessel, normally in the vapour space; wide-range thermocouples where exothermic processes could exceed normal temperatures.
Man-ways: usually 450–600 mm (18–24 in), unless an internal device needs larger. Vessels under about 750 mm diameter may take a flanged head; small vessels can have 200 mm inspection nozzles.
Vents and drains scale with the vessel volume: to 17 m³, 50 mm / 50 mm; 17–200 m³, 80/80; 200–400 m³, 80 drain / 100 vent; 400–700 m³, 100/150.
Summary
The process engineer defines T, P, size, orientation, metallurgy, nozzles, elevation and internals.
Vertical for gas-dominated and solids; horizontal for liquid-dominated and two liquids.
Level set-points divide the drum into hold-up and surge volumes with trips at the extremes.
Surge drums are sized from residence time, fill fraction and L/D.
Part 10 sizes the separators themselves: gravity settling, Souders–Brown, mist eliminators and three-phase vessels.