Process Hydraulics, Part 8: Parallel and Series Pumps, Displacement Pumps, Energy Cost and the Pump Datasheet
Running pumps in parallel and in series (and why unstable curves hunt), reciprocating and rotary pumps with their pulsation, power and slip, the energy cost of oversizing in rupees per year, and a complete walk through the process datasheet: flows and margins, pressures, design pressure, driver and materials.
SM
Sumit Mathur
22 min read
One pump rarely stands alone. Plants run spares, parallel trains, and pumps that must cover a wide range of flow. And not every liquid suits a centrifugal pump: viscous, high-pressure and metering duties belong to positive-displacement machines. This article covers pump combinations, displacement pumps, the economics of control, and the process datasheet that turns it all into a purchase.
This is Part 8 of 10. Part 7 covered a single centrifugal pump.
1. Pumps in parallel
Two or more pumps discharging into a common header . For identical pumps the combined curve is the single-pump curve with every flow doubled.
Points to understand before relying on parallel operation:
It gives step control only. Starting or stopping a pump changes flow in steps; fine control still needs a valve or speed control.
Stopping one pump does not halve the flow. The remaining pump slides out along its curve to a higher flow than half the two-pump total, because the system head is lower at lower flow. On a flat (high-static) system the effect is smaller; on a friction-dominated system the single pump runs well beyond its design flow.
Check the single-pump case thoroughly: the pump may now run at a flow above the design point, so verify NPSH and driver power at that flow.
Match the shut-off heads. If the pumps are not identical, the one with the lower shut-off head can be forced onto a dangerously low flow, or be held off the line by the stronger pump. Start the pumps against the check valve with care.
Unstable head curves (head rises with flow near shut-off) create several intersections with the system curve. When a second pump is brought on line, the combined system can hunt between operating points.
2. Pumps in series
Pumps in series add heads at the same flow. The discharge pressure of the first is the suction pressure of the second, so the casing and seal pressure rating of the downstream pump must be adjusted. In most cases a multistage pump replaces two pumps in series.
Explore both arrangements and see the effect of a static head and of an unstable curve:
Animation – Two pumps: parallel adds flow, series adds head
Operating flow
400 m³/h
Head
50 m
1 pump ÷ 2 pumps (flow)
79 %
Intersections
1
Parallel pumps add flow at the same head; series pumps add head at the same flow. With a flat system curve, a single pump of a pair delivers well over half the two-pump flow, so the remaining pump can run out to the end of its curve. An unstable (drooping-to-shutoff) head curve gives the system curve two intersections and invites hunting.
Switch to Unstable head curve: the system curve now cuts the pump curve in two places. The lower-flow intersection (dashed) is unstable, and the pump can bounce between the two when the demand changes.
3. Positive-displacement pumps
A displacement pump traps a volume of fluid and forces it into the discharge. Characteristics that differ from a centrifugal pump:
Flow is essentially constant for a given speed, nearly independent of discharge pressure. It falls slightly at higher pressure because of internal leakage (slip).
Pressure is limited only by mechanical strength or driver power. They will build pressure until something fails, so a relief valve on the discharge is mandatory, and never close a block valve downstream of a PD pump.
They are self-priming within limits, and flow control is by changing speed, stroke or by bypass, not by throttling.
Reciprocating pumps
Piston, plunger or diaphragm pumps driven by a crank. They handle very high pressures and a wide range of fluids, at the highest purchase and maintenance cost, and with large footprint and pulsating flow.
Power (kW) =36ηPdisch.
Displacement (theoretical) =ncyl×rpm×stroke×A×60 (m³/h, with SI units for stroke and area).
Slip is the loss of capacity by internal leakage, stuffing-box leakage and valve back-flow: typically 1–4 %, rising with discharge pressure and speed.
Efficiency is about 90 % for a single-stage and 88 % for a double-acting pump.
Speed is a critical selection criterion, governed by the suction-side hydraulics and the required life. The mean piston speed is typically 0.7–1.5 m/s.
Torque is constant for given suction and discharge: T(N⋅m)=P(kW)×9.549/rpm.
Large pumps (> 5 m³/h) are fixed-capacity and need a spill-back for flow variation. Small metering pumps adjust by stroke length (typically 20–100 %).
Diaphragm pumps inject and transfer chemicals; the diaphragm is PVC, PP, PVDF, stainless steel or Inconel, driven by a motor or a solenoid.
The discharge flow of a reciprocating pump is not steady. A simplex single-acting pump only delivers during half of each revolution. Add plungers and the gaps fill in. Pick a type and watch the combined flow:
Animation – Reciprocating pumps: why more plungers means smoother flow
Plungers
3
Peak ÷ mean
1.05
Min ÷ mean
0.91
Flow ripple
14 %
Each plunger discharges only part of the stroke, so a simplex pump delivers pulses with gaps. Staggering more plungers fills the gaps: a triplex still ripples by about 14 %, a quintuplex by about 5 %. Pulsation is why suction and discharge dampeners and a relief valve are standard on these pumps.
A triplex flow still ripples by about 14 %, a quintuplex by about 5 %; a simplex has gaps. That ripple is why pulsation dampeners (bladder or gas-cushion) go on the suction and discharge, and why velocities in reciprocating pump lines are kept low (Part 3).
Rotary pumps
Pump
Features
Typical limit
Screw
Flow axial and smooth, proportional to D3 and speed; handles a huge range of viscosity; self-priming; low churning
high cost; long screws for high pressure
Gear (external)
Two meshing gears; simple, old and widely used
~1500 gpm, 35 bar
Gear (internal)
Compact, handles viscous fluids well
~1100 gpm, 15 bar
Lobe
Single or multiple lobes; gentle with solids
~1000 gpm, 8.6 bar; common in wastewater/sludge
Rotary advantages: viscous fluids, non-pulsating flow. Limitations: high initial and maintenance cost, complex control, and cannot handle slurries or solids (except lobe or flexible-vane types).
Rotary vs centrifugal
Pressure: a rotary pump's head rises with the system; a centrifugal pump's falls with flow.
Viscosity: a centrifugal pump's efficiency collapses as viscosity rises; a rotary pump's efficiency actually improves with viscosity because slip drops. Above roughly 100–200 cP, or when the pump must run in a flow-independent, high-pressure duty, move to rotary or reciprocating.
4. What throttling costs: energy and money
Energy cost is where a pump spends its life. Take the oversized pump of Part 7, bought for 500 m³/h and run at 300 m³/h with a throttle valve. Compare it with a variable speed drive, or a properly sized pump. Set the required flow, the electricity tariff and the hours per year:
Interactive – What throttling costs you, in rupees per year
Flow / head
200 m³/h · 56.7 m
Efficiency
70 %
% of BEP flow
67 %
Shaft power
44.0 kW
Throttled, per year
Rs 15.8 lakh
Variable speed, per year
Rs 8.4 lakh
Saving
Rs 7.4 lakh
Pump speed (VSD)
79 %
A centrifugal pump runs where its head curve meets the system curve. Throttling slides the system curve up and burns the surplus head across the valve; slowing the pump slides the pump curve down instead, so no head is wasted. Dashed green is efficiency; the shaded band is the preferred operating range, 70–120 % of the best-efficiency flow.
At 200 m³/h required, with a Rs 6/kWh tariff and 6000 h/year, the throttled pump uses roughly twice the power of the variable-speed pump and costs several lakh rupees a year more. A rule worth remembering: the pump selection is the cheap part; the electricity is the cost.
Energy-saving routes and the usual causes they cure:
Cause
Fix
Oversized pump with throttling
Trim the impeller, fit a smaller one, reduce rpm, or use a VFD
Open bypass line
Close it, or re-size the pump
Several parallel pumps always on
Add controls to start/stop by demand
Batch operation with constant running
On–off control
High maintenance of seals and bearings
Operate near BEP; match capacity to requirement
5. The pump process datasheet
The datasheet is the interface between process design and the supplier. Everything the vendor needs to select a pump must be on it, and each number should be traceable to the heat and material balance and the hydraulics.
Identification
Item number and quantity, including how many run and how many are spare (operating philosophy). For parallel operation state the total capacity and head needed.
Service (the pump's name), type (centrifugal, metering, reciprocating, vertical submersible...).
Liquid handled: hydrocarbon, water, slurry; this selects materials and seals.
Fluid and operating data
Pumping temperature: normal, and min/max if the range is wide; include start-up.
Viscosity: from simulation or curves; for high viscosity state the minimum too, because it affects efficiency.
Vapour pressure at pumping temperature; for a liquid in equilibrium with vapour (reflux drum), the vessel's operating pressure is the vapour pressure.
Toxic, corrosive, or solids content.
Flow rates
State normal, maximum (with the design margin) and minimum (from turndown). For a centrifugal pump with a minimum flow below about 30 % of rated, a minimum-flow bypass is needed, and the pump is sized including the bypass flow. Typical margins over the normal flow:
Service
Margin
Continuous process pump
10 %
Reflux pump
20–25 %
Intermittent pump
0 %
Transfer pump
0–5 %
Large cooling-water pump
3–5 %
Recirculation pump
0 %
Boiler feed water (BFW) pump
25 %
Waste-heat boiler feed
30 %
(BFW margins vary between codes.)
Pressures
Suction pressure= source pressure + static head − suction friction (line, strainer, any equipment, valves, instruments).
Maximum suction pressure (for casing design) = design pressure of the source + the static head.
Discharge pressure= destination pressure + static head + discharge friction + margin. Use the highest liquid level for the static head; if an intermediate point is higher than the destination (a hump in the line), ensure there is enough pressure there above vapour pressure; add contingency for layout changes.
Design pressure: for centrifugal pumps, the maximum suction pressure plus the maximum differential pressure including a margin (typically 20 %); for positive displacement, about 1.1 × the discharge pressure.
Design temperature: the same as the source vessel.
Seal: mechanical seals for hydrocarbon service; packing for slurry or positive-displacement pumps.
Driver: electric motor, steam turbine or gas turbine per the design basis. Rate the motor above the pump's absorbed power:
Pump power
Motor nameplate as % of pump power
< 22 kW
125 %
22 – 55 kW
115 %
> 55 kW
110 %
Materials of construction
Choose on corrosion resistance, abrasive-wear resistance, cavitation resistance, mechanical properties (weldability, castability, machinability) and cost.
6. Exercise: the cost of oversizing
A pump was bought for 500 m³/h but the plant needs 300 m³/h. Throttled, about 28 m of head is burnt in the valve at 300 m³/h. The power for the throttled operation is 0.002725×Q×H/η; with variable speed to reduce the head, the power falls with the head and the efficiency rises. At Rs 6/kWh for 6000 h/year the saving is typically many lakh rupees per year. Use the energy lab above to compute your own case.
Summary
Parallel adds flow, series adds head; check the single-pump case, NPSH and power.
Unstable curves hunt: prefer rising-to-falling stable curves for parallel duty.
Positive-displacement pumps are constant-flow machines: always protect with a relief valve.
Pulsation falls steeply with the number of plungers.
The datasheet must define normal/max/min flow, pressures, NPSHa, design basis, driver and materials.
Part 9 turns from moving liquid to holding it: pressure vessels, supports, surge drums and level instrumentation.