Technical Safety Engineering, Part 6: SIS, SIL, LOPA and ALARP
How many layers of protection are enough? Safety instrumented systems and safety integrity levels in simple terms, layers of protection and independent protection layers, how a LOPA calculation finds the SIL a safety function needs (with a calculator), and what ALARP and tolerable risk mean, with a cost-benefit tool. Three interactive animations.
SM
Sumit Mathur
15 min read
A HAZOP tells you what can go wrong and what protects against it. It does not tell you whether those protections are enough. For that, engineers use three linked ideas: the safety instrumented system (SIS) and its integrity level (SIL), the layer of protection analysis (LOPA) that finds the SIL needed, and the ALARP principle that says when to stop adding protection.
This is . described the HAZOP. The next part () is the full quantitative risk assessment.
A safety instrumented system is a dedicated instrumented system, independent of the basic process control, that protects against undesirable health, safety and environmental events. It can also protect against financial events such as business interruption and equipment damage.
It has three parts: a sensor, a logic solver and a final element (typically a valve). When the sensor sees a dangerous condition, the logic solver closes the valve.
Examples:
HIPPS (high-integrity pressure protection system), which shuts off the source of pressure before it can overpressure a vessel,
shut-off of fuel gas to a furnace,
a high-level trip on a compressor knock-out drum.
The system does the same job as the control system, but it is a separate set of sensors and valves. The control system is the one that fails and causes the problem. The SIS must not fail with it.
2. Safety integrity level (SIL)
The safety integrity level (SIL) is how we measure how well a safety function performs. It is the required availability of the safety function when the process demands it. It is stated as the probability of failure on demand (PFD).
SIL
PFD
Availability
Risk reduction factor
1
10⁻¹ to 10⁻²
90 – 99 %
10 – 100
2
10⁻² to 10⁻³
99 – 99.9 %
100 – 1 000
3
10⁻³ to 10⁻⁴
99.9 – 99.99 %
1 000 – 10 000
4
10⁻⁴ to 10⁻⁵
99.99 – 99.999 %
10 000 – 100 000
There are four SIL levels in the standard IEC 61511 for the process industry (SIL 4 is rarely used). A higher SIL means:
stricter technical and non-technical requirements (design rules, testing, management),
a safety function that fails less often,
more protection available, but a higher cost.
SIL can be seen from three points of view:
process owners: which safety functions do I need, and how much risk reduction from each?
engineers and integrators: how do I build a system that meets that SIL?
operators: how do I operate, test and maintain it to keep that SIL?
What a safety integrity level means
Typical probability of failure on demand
3.2 × 10⁻³
Failed on demand, about once every
3162 years
Demands per year
0.10
Examples of safety instrumented systems: high-integrity pressure protection (HIPPS), furnace fuel gas shut-off, and a high-level trip on a compressor knock-out drum. A higher SIL means stricter design rules, better testing and more redundancy, and a higher cost.
A safety function waits, often for years, until it is needed. Its integrity level is the probability that it fails when the demand comes (PFD). Each level is ten times better than the one before. Pick a level and say how often the process demands the function, to see how often the demand would meet a failed function. IEC 61511 defines the levels for the process industry. SIL 4 is rarely used in process plants.
3. Layers of protection
No single barrier is perfect. Safety comes from several independent layers, like the layers of an onion. From the centre outward:
Process design (the plant is designed safe to start with),
For a harmful event to happen, the initiating event must get through every layer. This is the idea behind the “Swiss cheese” picture: each layer has holes, but the holes in different layers rarely line up.
4. LOPA: layer of protection analysis
LOPA is a simplified process risk assessment. It evaluates how effective the independent protection layers are in lowering the likelihood (or severity) of an undesirable event. It uses repeatable look-up tables to give a value to each cause and consequence, and then reduces the risk by the credit of each layer to find what is left.
It is most often used to find the SIL requirement for a safety instrumented function.
Independent protection layer (IPL)
An IPL is a device, system or action that can stop a scenario from reaching its undesired consequence, independent of the initiating event and of the action of any other layer. Its effectiveness and independence must be auditable.
So a layer does not count if:
it uses the same sensor, logic or valve as the cause or another layer,
its performance cannot be shown.
The calculation
Calculated method:
foutcome=finitiating×(modifiers)×
The result is the residual frequency of the bad outcome. It must be lower than the tolerable frequency for that severity. If it is not, the gap shows the extra risk reduction needed, and so the SIL.
PFD required=fresidualftolerable
(The factor method does the same with the exponents: initiating event factor minus the sum of the IPL factors.)
Typical example values:
Initiating event
Frequency per year
Factor
Instrument failure
10⁻¹
1
Logic solver failure
10⁻²
2
Pump stops (no flow)
10⁻¹
1
Pipe leak
10⁻³
3
Protection layer
PFD
Credit factor
Check valve
1
0 (no credit)
Alarm and operator response
10⁻¹
1
Relief valve (PSV)
10⁻²
2
SIL 1 function
10⁻¹
1
SIL 2 function
10⁻²
2
SIL 3 function
10⁻³
3
Modifiers (enabling conditions) may also be used: the chance that there is ignition, that a person is in the area, that a given weather occurs. They lower the frequency, since the outcome needs them to be true.
Try it
Pick an initiating event and a severity, switch layers on and off, and see what SIL is needed.
LOPA: how many layers of protection are enough?
Initiating event10⁻¹ / yr
Ignition and people present2.5 × 10⁻² / yr
Alarm and operator response2.5 × 10⁻³ / yr
Red line: tolerable frequency for “one fatality”.
Frequency of the bad outcome
2.5 × 10⁻³ / yr
Tolerable frequency
10⁻⁵ / yr
Extra risk reduction needed
250 times
Safety function needed
SIL 3
A layer only counts if it is independent of the cause and of the other layers, and if its performance can be shown. A check valve gets no credit here. Two alarms driven by the same sensor are one layer, not two.
Layer of protection analysis starts with how often the initiating event happens. Every independent protection layer (IPL) multiplies that frequency by its probability of failing on demand (PFD). The result is the frequency of the bad outcome, which is compared with the tolerable frequency for that severity. If it is still too high, the gap tells which safety integrity level (SIL) a new safety function needs. The PFDs are the usual textbook values, and the tolerable frequencies are examples: your client or company sets them.
Things to try:
Start with only the alarm switched on. It is not enough for a fatality.
Add the relief valve. Notice how much one layer with a PFD of 0.01 does.
Choose “several fatalities”. The tolerable frequency is ten times smaller, so the SIL needed rises.
Add a SIL 2 function and see the residual frequency drop below the red line.
When and who
LOPA uses the results of the HAZOP (the cause and consequence events and the safeguards), so it is done after the HAZOP. It essentially breaks down the HAZOP risk-ranking matrix. Because it affects the P&IDs (the instrumentation), a preliminary SIS/SIL assessment is often done earlier, after the first hazard review. The risk tolerance criteria must come from the client or the company. LOPA is a frequent topic on projects. It is a relatively new technique (about 1998) and is now widely accepted.
5. Risk, tolerable risk and ALARP
Risk is often mixed up with consequence. Remember:
R=F×C
A scenario with a high-severity consequence may still have a very low risk if its frequency is tiny. There are two kinds of risk: those that can be eliminated (by inherently safer design) and those that can only be minimised.
ALARP means As Low As Reasonably Practicable. The concept is that efforts to reduce risk should continue until the extra sacrifice (cost, time, effort) is grossly disproportionate to the extra reduction in risk. The risk is placed in one of three bands:
Intolerable: the risk must be reduced whatever the cost. Without a reduction the activity does not go ahead.
ALARP region: reduce the risk if it is reasonable to do so. A measure can be left out only if a cost-benefit analysis shows that its cost is far out of proportion to the benefit.
Broadly acceptable: the risk is low. No further reduction is needed beyond keeping the controls working.
The limits are set by the regulator or company. A common framework (UK HSE style) uses about 10⁻³ per year as the upper limit for a worker and 10⁻⁶ per year as the lower, broadly acceptable level.
ALARP: how far must risk be reduced?
Risk is
ALARP region
Benefit of the measure
4.0 × 10³
Cost ÷ benefit
50.00
Is it grossly disproportionate?
yes: may be rejected
The measure costs far more than the risk it removes, so it may be left out, and the decision should be recorded.
Benefit = risk removed × value of preventing a fatality (here 10 million) × 20 years. The cost-benefit method is one part of the argument. Good practice and the opinions of the people affected also count.
Risk is sorted into three bands. Above the upper limit it is intolerable and must be reduced whatever the cost. Below the lower limit it is broadly acceptable. In between, risk must be reduced until the cost of doing more is grossly out of proportion to the benefit. The limits and the value of a life used here are examples in the style of the UK HSE framework (worker risk 10⁻³ and 10⁻⁶ per year). Companies and regulators set their own.
Things to try:
Put the individual risk at 10⁻⁷: the risk is already broadly acceptable.
Put it at 10⁻⁴ and increase the cost of the measure until it becomes “grossly disproportionate”.
Raise the “gross disproportion factor”. The higher the starting risk, the higher the factor that is applied.
6. How the pieces fit together
HAZOP finds the scenarios and the existing safeguards.
LOPA gives each scenario a frequency and shows if the safeguards are enough.
Where they are not, a safety instrumented function with a SIL is added.
The SIS is designed, tested and maintained to meet its SIL.
ALARP decides when no more needs to be done.
7. Common mistakes
Giving credit to layers that are not independent (two alarms on the same sensor).
Giving credit to a check valve or to an operator with no time to act.
Over-specifying SIL (high cost) or under-specifying it (high risk) because the tolerable frequency was not agreed first.
Forgetting that a SIL is only held if the function is tested and maintained.
Treating a risk number as exact. It is an input to a decision, not the decision.
Summary
A safety instrumented system is an independent sensor, logic solver and valve that shuts down a hazardous process.
The SIL is the required reliability on demand. Each level is ten times better than the one before.
Safety comes from independent layers. An initiating event must pass through every layer.
LOPA multiplies the initiating frequency by the PFD of each independent layer, and compares the result with the tolerable frequency. The gap gives the SIL.
Risk = frequency × consequence. ALARP: reduce risk until the cost of doing more is grossly out of proportion to the benefit.
Part 7 closes the series with the quantitative risk assessment: leaks, dispersion, fires, explosions, event trees and risk criteria.