Process SafetyProcess SafetyQRAQuantitative Risk AssessmentEvent TreeFN CurveConsequence ModellingDispersionIndividual RiskAnimatedTechnical Safety Engineering Series
Technical Safety Engineering, Part 7: Quantitative Risk Assessment
How a plant's risk is turned into numbers: the five questions of a QRA, leak sizes, inventory and isolation time, release rates, wind and gas dispersion, jet fire, pool fire, flash fire, explosion, BLEVE and toxic effects, an event tree with real numbers, individual and societal risk (FN curve), risk criteria, and how risk is reduced. Five interactive animations.
SM
Sumit Mathur
18 min read
A HAZOP says a leak could happen. A quantitative risk assessment (QRA) says how often, how far its effects reach, how many people would be hurt, and whether that is acceptable. It is the most detailed of the safety studies, and it is how a plant shows, with numbers, that its risks are low enough.
A QRA expresses risk in numbers for people, the environment and the business. It answers five simple questions. Each one has its technical name.
A quantitative risk assessment in five questions
How it is done
Study the flow diagrams, piping and instrument diagrams, process description, layout and the HAZOP. List every credible loss of containment: leaks and ruptures of vessels, pipes, pumps, valves.
What comes out
A list of scenarios, grouped into isolatable sections.
A QRA turns the question “is this plant safe enough?” into numbers. It answers five simple questions in order. If the answer to the last one is “not yet”, the loop starts again with the improved design. Play the animation, or click a question.
Question
Technical activity
What can go wrong?
Hazard identification
How often?
Frequency estimation
How bad?
Consequence modelling
So what?
Risk assessment
What do I do?
Risk management
The main objective is to estimate the risk levels for personnel from accidental releases of hazardous material (loss of containment) and from toxic gas, and to demonstrate that they are ALARP. The results show which accident scenarios add most to the total risk, and so help decisions.
The overall method:
Identify the process hazards of the facility.
Find the consequences of hydrocarbon releases from piping and equipment.
Find the frequency of those releases.
Calculate individual risk and societal risk.
Compare with the risk tolerance criteria.
If the risk is not as low as reasonable, look for risk reduction measures, add them, and calculate again.
2. Hazard identification
This is the critical first step. The team studies the operations and the documents, such as flow diagrams, P&IDs, the heat and material balance, the process description, the HAZOP report and the plot layout. Methods include what-if analysis, HAZOP and preliminary hazard analysis. All potential incidents are identified and recorded.
3. Failure frequency
Frequencies come from a parts count: count the components in each section (actuated valves, manual valves, flanges, instrument connections, vessels, rotating equipment), and give each a leak frequency from a failure-rate database such as the OGP risk assessment data directory (or EIGA and UK HSE data). The sum is the leak frequency of the section for each hole size.
4. How much gas leaks? Size, inventory and isolation time
Leak size
The leak size is the physical opening through which fluid can escape. QRA studies consider both leaks and complete ruptures. The sizes follow accepted guidelines (OGP 434-04, the Purple Book CPR 18E, EGIG) or the client. A common grouping:
Hole size
Class
2 – 5 mm
Pin leak
5 – 10 mm
Small leak
10 – 50 mm
Medium leak
50 mm or more, or rupture
Full bore / catastrophic release
These are not fixed. They vary with the guideline, the project and the client.
Inventory and isolation
The quantity that can leak depends on the isolatable section: a segment of the process (a vessel or a pipeline) that can be shut off by an automatic valve, by manual action, or from the control system.
Total inventory=Static inventory+Dynamic inventory
Static inventory: the material trapped in the section after isolation (valves closed in an emergency shutdown).
Dynamic inventory: the material that keeps coming in from the process flow during the isolatable time, the time it takes to isolate or depressurise the section after a loss of containment.
An inventory sheet is prepared for each isolatable section: its hazardous material, volume, pressure, temperature, pipe size, flow rate, response time and the total inventory.
The faster the isolation, and the smaller the section, the less can escape. Look at how the release behaves:
How much escapes before the leak is isolated?
Release rate at the start
3.0 kg/s
Released by 300 s
778 kg
Share of the section
26 %
Size class
Medium leak
Typical size classes: pin leak 2–5 mm, small 5–10 mm, medium 10–50 mm, and 50 mm or more (up to a full-bore rupture) is the catastrophic case. Classes are not fixed: the guideline, the project and the client may change them.
The hole size decides the release rate. The inventory in the isolatable section, plus anything that keeps flowing in until the valves close, decides the total. A leak cannot release more than the inventory that is available, so the curve bends over. This is why quick isolation and small isolatable sections are such strong safety measures. Gas is treated as ideal and the flow as choked, so the numbers are indicative.
Things to try:
Make the hole bigger. The release rate rises, but the total cannot be more than the inventory.
Shorten the time to isolate. The mass that escapes falls sharply for a big hole, little for a pin hole.
Add a “feed still flowing in”. The curve no longer bends over, because new gas keeps coming.
Reduce the gas in the isolated section. This is the effect of making the sections smaller, and of quick blowdown (see Depressurization).
5. Consequence modelling
The main hazardous events are fire, explosion and toxic release. The aim is to find the worst cases and how they affect people and the environment. For each accident scenario, the physical effects are found as distances: to a given heat radiation, overpressure or concentration, or to the flammability limits.
Accidents that release hazardous material can cause gas dispersion, jet fire, flash fire, explosion or a combination. The cases are chosen by assuming leaks from vessels, piping, pumps, compressors and valves in the most dangerous sections, from the fluid, the conditions and the inventory. Validated software (such as Phast and Safeti) is used for the modelling. It needs weather data, source parameters and terrain, and it gives plume, radiation and overpressure results.
The hazard events
Jet fire: a turbulent flame from a flammable material released continuously with high momentum in one direction.
Pool fire: a turbulent diffusion fire above a horizontal pool of liquid that gives off vapour, with zero or very low initial momentum.
Vapour cloud explosion (VCE): a large enough release mixes with air and is ignited, and the burning cloud makes a pressure wave.
BLEVE: a liquid held above its atmospheric boiling point is suddenly depressurised and flashes to vapour with a large energy release.
Flash fire: a sudden brief fire from the ignition of a dispersed vapour cloud. The flame front moves fast, and the fire goes out when the fuel is consumed.
(The first two are in Part 2.) A flammable cloud can burn only between its lower and upper flammability limits.
Weather: wind and stability
Wind speed, temperature, humidity and the Pasquill stability class (A, very unstable, to F, stable) are key inputs to dispersion. The classes are named after the British meteorologist who proposed them in the 1960s.
Low wind gives limited dilution and higher gas concentrations near the source.
Moderate wind speeds up dispersion, lowering local concentration but spreading the cloud farther downwind.
High wind dilutes quickly, but may bend flames or spread a fire.
A gas cloud grows as it moves, and its peak concentration at the centre falls. Eventually it drops below the level at which the gas is hazardous. The distance a cloud travels is simply:
Distance=Wind velocity×Time
Wind, stability and how far a flammable cloud reaches
Distance to the lower flammable limit
59 m
Distance to half the limit
85 m
Time for the cloud to get there
20 s
Air condition
D: neutral
overcast or windy: the most common class. Try class F with 1 m/s of wind, then class D with 8 m/s: strong wind dilutes the cloud and shortens it, but it also brings the cloud to a downwind ignition source faster.
A gas that leaks at ground level is carried downwind and mixes with air. The distance it travels equals the wind speed times the time. How far the cloud stays flammable depends on the release rate, the wind speed and the stability of the air, which Pasquill grouped into classes A (very unstable) to F (stable). A calm, clear night (F) keeps the cloud thin and long. A simple textbook model of a steady release of a gas with about the density of air is used here. Real studies use dispersion software and local weather data.
Things to try:
Choose F (stable) with 1 m/s of wind: the cloud is long and thin and stays flammable a long way.
Choose A (very unstable): the same leak is much shorter.
Raise the release rate by 10 and note how the distance grows, but by much less than 10 times.
Compare methane and hydrogen. Their flammable limits differ, and so does their density, which a real study must also account for.
Toxic, explosion and thermal effects
Toxic release. A toxic cloud harms people who come into contact with it. Exposure limits are based on:
IDLH (immediately dangerous to life or health): the concentration a healthy worker could be exposed to for 30 minutes (if a respirator fails) without lasting effects or impaired escape.
STEL (short-term exposure limit): the maximum average concentration for 15 minutes.
ERPG (emergency response planning guidelines): the highest airborne concentration nearly all people can be exposed to for up to an hour without various effects.
LC50: the concentration lethal to half of those exposed.
Explosion. An explosion is a rapid release of energy. In a gas, the sudden expansion pushes back the surrounding gas, and a blast wave moves outward. Two ways to estimate the overpressure:
TNT equivalency: equate the energy of the fuel to a mass of TNT. It does not consider confinement or congestion, and tends to overpredict near the explosion and underpredict farther away.
TNO multi-energy method: finds the confined volumes in the process, assigns a degree of confinement or congestion, and gives the overpressure contribution of each.
The effects are measured as: heat radiation in kW/m² (for fires), overpressure in bar (for explosions), and concentration in ppm (for toxic gas). Damage thresholds then link them to harm. Commonly used values are about 1.6 kW/m² (no discomfort for long exposure), 4.7 kW/m² (pain within about 15 – 20 s), 12.5 kW/m² (a small chance of death in a minute, and ignition of wood), and 37.5 kW/m² (severe equipment damage and very high lethality). Overpressure of about 0.02 – 0.03 bar breaks windows, 0.1 – 0.2 bar damages buildings, and 0.7 bar can destroy them.
6. The event tree
A leak does not always end in an explosion. What happens depends on a series of yes/no events: is there immediate ignition? Does the wind blow toward people? Is there delayed ignition? An event tree shows this: a graphic of a logic model that identifies and quantifies the possible outcomes of an initiating event. The outcomes can be direct (fires, explosions) or indirect (domino effects on neighbouring plants). Each branch has a probability, often binary (yes or no).
Example: a large leak of pressurised LPG from a storage tank, with a frequency of 10⁻⁴ per year.
Event
Probability
Source
Immediate ignition at the tank
0.1
Expert opinion
Wind blowing toward a populated area
0.15
Wind rose data
Delayed ignition near the populated area
0.9
Expert opinion
Vapour cloud explosion rather than flash fire
0.5
Historical data
Jet flame hits the LPG tank
0.2
Tank layout geometry
An event tree: what can a leak turn into?
BLEVE2.0 × 10⁻⁶ / yr
Leak: 10⁻⁴×Ignites at once: 0.1×Jet flame hits the tank: 0.2
Local thermal hazard (jet fire)8.0 × 10⁻⁶ / yr
Leak: 10⁻⁴×Ignites at once: 0.1×Jet misses the tank: 0.8
Leak: 10⁻⁴×No immediate ignition: 0.9×Wind toward people: 0.15×Delayed ignition: 0.9×Burns as flash fire: 0.5×Flame hits the tank: 0.2
Flash fire4.9 × 10⁻⁶ / yr
Leak: 10⁻⁴×No immediate ignition: 0.9×Wind toward people: 0.15×Delayed ignition: 0.9×Burns as flash fire: 0.5×Flame misses the tank: 0.8
Safe dispersal7.8 × 10⁻⁵ / yr
Leak: 10⁻⁴×No immediate ignition: 0.9×Wind away, or no ignition: 0.86
All outcomes add up to
10⁻⁴ / yr
Leak frequency
10⁻⁴ / yr
Chance a leak ends safely
78 %
Chance of an explosion
6.1 %
An event tree follows one initiating event, a large leak from a pressurised LPG tank, through a series of yes/no questions. Each branch has a probability, and the frequency of an outcome is the leak frequency times the probabilities along its path. The six outcomes add up to the leak frequency. The default numbers are the ones from a worked textbook example. Change them and see which outcomes dominate.
The outcomes are, in frequency per year:
BLEVE (immediate ignition and jet hits the tank): 2.0 × 10⁻⁶,
local thermal hazard: 8.0 × 10⁻⁶,
vapour cloud explosion: 6.1 × 10⁻⁶,
flash fire and BLEVE: 1.2 × 10⁻⁶,
flash fire: 4.9 × 10⁻⁶,
safe dispersal: 77.9 × 10⁻⁶.
All six add up to the leak frequency, 100 × 10⁻⁶ = 10⁻⁴. Most leaks end safely. The rare outcomes are the ones that dominate the risk.
7. Calculating risk
Risk=Severity×Likelihood=Consequence×Failure frequency
For people:
Risk for people [deaths/year]=Frequency [events/year]×Damage [deaths/event]
Two kinds are reported:
Individual risk (IR): the risk to one person. Location-specific individual risk (LSIR) is the risk for a person who is at that spot 24 hours a day, 365 days a year. It is shown as iso-risk contours on a plan. Because nobody stays at one place all the time, the real individual risk is lower: the LSIR times the share of the year spent there. Individual risk criteria protect each worker. They are expressed per year or as a fatal accident rate (FAR).
Societal risk: the risk of accidents with many deaths. It is shown on an FN curve: the cumulative frequency (F) of accidents that kill N or more people against N. Human vulnerability is found from probit equations of thermal radiation, overpressure and toxic concentration.
Societal risk: the FN curve, and individual risk
Societal risk is
ALARP region
Individual risk
2.3 × 10⁻⁶ / yr
Location-specific individual risk (LSIR) is the risk to a person who is at that spot all the time, 24 hours a day, 365 days a year. Nobody does that, so the individual risk of a real person is the LSIR times the share of the year spent there. Plots of equal LSIR on a plan are called risk contours.
The lines drawn here are F = 10⁻²/N (upper) and F = 10⁻⁴/N (lower). The calculated outcomes (BLEVE, vapour cloud explosion, flash fire and local fire) are given the fatality numbers shown in the plot, scaled by “people exposed”.
Societal risk asks how often an accident kills N or more people. The FN curve plots that cumulative frequency (F) against N, on log scales. Two criteria lines divide the plot into an intolerable region (top), an ALARP region (middle) and an acceptable region (bottom). Raise the leak frequency or the number of people exposed, and the curve climbs. Cut the frequency with safeguards, and it falls. The criteria lines here are examples. Individual risk is the risk to one person, and it falls with the time spent at a location.
8. Risk criteria
The criteria translate a number (such as 10⁻⁷ per year) into a judgement. A flexible framework divides risk into three bands:
an unacceptable (intolerable) region, where risk reduction is essential,
a middle band, the ALARP region, where risk reduction is desirable but may not be done if the cost is far out of proportion to the benefit,
a negligible (acceptable) region, where no further reduction is needed.
On an FN plot, the top region is intolerable, the middle is ALARP, and the bottom is acceptable. If the plant’s FN curve reaches the top region, action is mandatory.
9. Assumptions and risk reduction
An assumption register states the rule sets, statistical data, impact criteria and other assumptions used, so that the results can be understood and checked.
The risk from a fire, explosion or toxic release can be reduced in three ways:
Elimination: remove the hazard, if the design intent can still be met.
Reduce the frequency: use less hazardous materials, lower pressure or temperature, and process interlocks and shutdown systems.
Reduce the consequences: minimise inventories, siting and layout of the plant, emergency plans and procedures, avoid ignition sources, and secondary containment.
10. Common mistakes
Using a generic leak frequency without checking the parts count.
Forgetting that the isolation time (or failing isolation valves) controls the inventory released.
One wind and one stability class for the whole year, where the weather varies.
Treating the number as exact. The assumptions, not the digits, make the answer.
Looking only at individual risk and missing the societal risk of a large group in one place.
Not feeding the QRA results back into the layout and design while changes are cheap.
Summary
A QRA answers: What can go wrong? How often? How bad? So what? What do I do?
Frequency comes from a parts count with failure data. Consequence starts from leak size, inventory and isolation time.
Fires (jet, pool, flash, BLEVE), explosions and toxic clouds are modelled with weather data. Distance travelled equals wind speed times time.
An event tree multiplies the probabilities of the branches. Most leaks end safely, but rare outcomes dominate the risk.
Individual risk and societal risk (FN curve) are compared with intolerable, ALARP and acceptable bands.
Risk is reduced by elimination, by lowering the frequency and by lowering the consequence.