Shell & Tube Heat Exchangers, Part 6: Reboilers, Boiling and Special Exchangers
Kettle vs thermosiphon vs forced circulation, the pool-boiling curve and why heat flux has a ceiling, flow regimes in tube-side boiling, thermosiphon piping, plus waste heat boilers, hairpins, bayonet exchangers and IBR. A reboiler selector and a boiling-curve animation.
SM
Sumit Mathur
19 min read
Everything so far assumed the fluids stay single-phase. Add boiling and the rules change: heat flux has a ceiling, flow patterns appear inside the tubes, and hydraulics become part of the thermal design. This article covers reboilers and a few special-purpose exchangers.
This is Part 6 of 7. Part 5 covered tuning a design.
1. Two families of reboiler
A reboiler returns heat to the bottom of a distillation column by boiling part of the bottoms.
Natural circulation (thermosiphon): the liquid column feeding the reboiler is denser than the vapour–liquid mixture leaving it. That difference in hydrostatic head drives the flow, with no pump.
Forced circulation: a pump sets the flow.
The thermosiphon types are vertical (boiling inside the tubes, E shell, fixed tubesheet, usually triangular pitch), horizontal (boiling on the shell side, G, H, J or X shells), and the kettle (a K shell with a built-in vapour-disengagement space). Forced circulation is usually a horizontal exchanger with the boiling side in the tubes.
2. Choosing a reboiler
Select by the dominating constraint. The first table summarises how process conditions point to a type; the animation shows the flow loop for each. Click through the cases:
Interactive – Which reboiler for which duty?
Recommended
Vertical thermosiphon
Vertical, tube-side boiling, E shell
Cheap, compact, self-circulating and the fast flow keeps tubes cleaner. The default choice when nothing is extreme.
+ Compact, cheap, no pump, resists fouling
− Needs column elevation; flow regime and static head matter
Pick the condition that dominates your column and see the reboiler type usually recommended, its flow loop, and why. This follows common selection practice; always check against the actual heat-flux and hydraulic calculation.
A second view is a decision flow. If the vapour fraction is below about 30 %, a thermosiphon is generally fine. Above that, asking about viscosity, whether there is a bottom pump, and whether the tower can be elevated sorts the choices between vertical thermosiphon, horizontal thermosiphon, kettle and forced circulation. For area above ~600 ft² or viscosity above ~2 cP a kettle or forced circulation tends to win.
A third view looks at the fouling. For very heavy fouling use forced circulation or a vertical thermosiphon; for clean service at low pressure a kettle is acceptable.
Falling-film evaporators may be preferred in three cases: very low MTD, viscous liquids, and deep vacuum where even a kettle carries too much static head.
3. Pool boiling versus flow boiling
Pool boiling
Flow boiling
Agitation
Bubbles and natural convection only
Bubbles, natural convection and flow
Fluid velocity
Negligible
Matters
Depends on
Surface tension, latent heat, ΔT
Surface tension, latent heat, ΔT, liquid/vapour ratio
Liquid/vapour ratio
No effect
Affects the coefficient
Test yourself: if you raise the circulation rate through a kettle by 20 %, what happens to the boiling coefficient? Almost nothing, because a kettle is pool boiling and velocity barely matters.
4. The boiling curve and the heat-flux ceiling
Heat the wall hotter and hotter against a pool of liquid and the flux does not rise forever:
Natural convection at small superheats.
Nucleate boiling: bubbles stir the liquid, flux climbs steeply. This is where reboilers live.
Peak (critical heat flux) at the end of the nucleate range.
Transition and then film boiling: vapour forms faster than it can leave, blankets the wall, and the flux falls despite a larger ΔT.
Animation – The pool-boiling curve: why reboilers have a heat-flux limit
ΔT
1 K
Heat flux vs peak
1 %
Regime
Natural convection
Reboiler zone?
no
Few bubbles; liquid just circulates. Heat flux is modest.
Raise the wall-to-liquid temperature difference and the flux climbs through nucleate boiling to a peak. Push past it and a vapour film blankets the surface; flux collapses even though the driving force keeps growing. Reboilers must stay left of the peak. (Schematic, log–log.)
Hence the design limits that stop you straying right of the peak:
Limit
Value
Max flux, natural-circulation reboiler
~15,000 Btu/h·ft² (≈ 47 kW/m²)
Max flux, forced-circulation reboiler
~20,000 Btu/h·ft² (≈ 63 kW/m²)
Max flux for water
~30,000 Btu/h·ft² (≈ 95 kW/m²)
Max vaporising coefficient
~300 Btu/h·ft²·°F (≈ 1.7 kW/m²K)
Steam-heated reboiler: investigate if LMTD exceeds
~90 °F (50 K), where film boiling begins
Minimum wall-to-fluid ΔT
~5 °F (≈ 3 K), or the regime reverts to natural convection
These are conservative rules of thumb for moderate pressures (especially for water). At very high or very low pressures the real maximum flux can be much lower, and it also depends on geometry: it falls as bundle diameter grows at fixed pitch, and as pitch narrows at fixed bundle diameter. For kettles and horizontal thermosiphons there is an empirical flux equation; for vertical thermosiphons a chart. Remember also that a clean start-up has higher coefficients and can run at higher flux than the design case.
Enhanced boiling tubes
Surface-enhanced tubes make bubbles form at much lower superheat. A porous-coated tube (a thin ~1.6 mm sintered metal layer) draws liquid in by capillarity to a vast number of stable nucleation sites. Boiling-side coefficients can be 10–30 times those of a bare tube and overall coefficients 2–4 times, with stable boiling at very low ΔT. Micro-fin and corrugated tubes are milder alternatives. They shrink the shell count in new plants, and in a revamp they add capacity without a new exchanger. Typical uses are ethylene, propylene and other refrigeration-service evaporators.
5. Flow regimes inside tube-side boiling
In a vertical thermosiphon the fluid changes character as it boils its way up: bubbly, slug, annular, and finally mist. Coefficients are best when liquid touches the wall.
Avoid mist flow. The wall goes dry, droplets fly through a vapour core, and heat transfer collapses. Keep vaporisation to around 30–33 % by weight.
The higher the vapour fraction, the lower the velocity must be to stay out of mist. As an example, with 50 % vaporisation and vapour density 1 lb/ft³ the velocity should stay below about 80 ft/s; at 75 % it falls to about 30 ft/s. Horizontal tubes, where flow stratifies, tolerate far less.
Slug flow is undesirable but common in thermosiphons because the vaporisation is set by the column's energy need. A forced-circulation system avoids it.
The Fair chart uses the Martinelli parameter Xtt, which grows with vapour fraction and liquid density, to map the regimes.
6. Thermosiphon piping
The reboiler and its piping are one hydraulic circuit: the driving head must exceed all the friction and exit/entrance losses. Useful checks:
Entrance loss at the column inlet is about 1.0 velocity head and the exit loss at the column outlet is about 0.5.
For ~30 % vaporisation, inlet piping with 12<d2/Q<15 and outlet piping with 24<d2 ( in inches, in MMBtu/h) is a sensible first size.
Do not isolate a reboiler with a valve unless a separate PSV is added, since the valve adds resistance and spoils the hydraulics.
7. Special exchangers
Waste heat boiler
Mostly horizontal, behind ethylene-cracking furnaces, steam-methane reformers, Claus reactors and similar process-gas sources. Steam is raised on the shell side because the hot gas is very fouling, a fixed tubesheet with triangular pitch fits many tubes and keeps cost down, and differential expansion is small.
Size the tube count to keep inlet-gas velocity near 100 ft/s (about 30 m/s). Typical tubes are 2.5″ OD for catalyst-regenerator flue gas and 1.5″ OD for reformer effluent.
Keep tubes wet with enough circulation: a water/steam weight ratio of about 10:1 at 15,000 Btu/h·ft², 15:1 at 25,000 and 40:1 at 100,000.
Both tubesheets are fixed, so differential expansion loads them heavily. Make them thin (15–30 mm) so they act like a flexible membrane, which also keeps the gas-side metal near the water temperature (preferably below 600 °C), cooling a 900 °C gas to 500 °C within a very short distance and avoiding metal dusting.
Double-pipe and hairpin
Choose them for small area (under ~50 m²), a temperature cross on a small flow, liquid flow below about 150,000 lb/h (68 t/h), or modest gas flow.
Bayonet exchanger
A small tube sits inside a larger tube that is capped at one end. Fluid enters the inner tube, turns at the cap and returns through the annulus, so heat crosses mostly through the outer tube. Inner and outer tubes are fitted to separate stationary tubesheets, so each can be pulled for cleaning.
Uses: vaporisers for propylene, ammonia, LPG, butane; heating of large tanks and vessels instead of a jacket (more area).
Benefits: a non-freezing tube side for steam heating of cryogenic fluids (the steam in the inner tube keeps condensate warm), small footprint, low hold-up, no thermal-expansion stress (free at one end), very high turn-down, and self-regulating liquid level and vaporisation rate.
IBR
In regions that apply the Indian Boiler Regulations (or equivalent steam-boiler codes), exchangers that generate steam, either as the main duty or as a by-product, and steam superheaters need regulatory review and approval. Exchangers that merely condense steam do not.
Summary
The reboiler type follows the constraint: pressure, MTD, fouling, boiling range, vacuum.
Stay left of the boiling peak: apply the heat-flux and ΔT limits.
Keep tube-side boiling out of mist flow.
Treat reboiler piping as part of the exchanger.
Part 7 ties everything together with a hand-calculation procedure and the effectiveness–NTU method.