Fluid Flow & HydraulicsHydraulicsPressure ProfileControl ValveEquipment ElevationNPSHHydraulic Flow DiagramAnimatedHydraulics Series
Process Hydraulics, Part 6: The Hydraulic Pressure Profile, Equipment Elevation and Control-Valve Pressure Drop
How to build a hydraulic calculation for a whole circuit: fixed pressure points, hydraulic flow diagrams, normal, design and turndown cases, setting column and receiver elevations from NPSH, equipment pressure drops, control-valve rules, and pro-rating friction. An animated pressure waterfall.
SM
Sumit Mathur
21 min read
So far we have sized individual lines. A plant is a network of lines, vessels, exchangers, pumps and valves, and the question that matters is: at every point of this circuit, what is the pressure, at every flow we will operate? That calculation is the hydraulic analysis, or just "hydraulics." It sizes pumps and compressors, sets equipment elevations, gives control valves their pressure drop, and proves a unit will actually run.
This is Part 6 of 10. Part 5 covered two-phase lines.
A hydraulic analysis is a pressure profile calculation through piping and equipment, repeated for each expected flow case:
100 % normal flow: the design point.
110–120 % turn-up flow: headroom for upsets, uncertainty in the final layout, and future debottlenecking.
50–60 % turndown flow: where control-valve pressure drop is greatest and the pump runs furthest back on its curve.
Other operating scenarios: start-of-run and end-of-run catalyst, plugged reactors, summer and winter, lean and rich feed.
It answers practical questions:
How much head must each pump or compressor deliver?
How much pressure drop can each control valve have?
What is the design pressure of each vessel, based on the highest hydraulic pressure it can see?
Will the unit work at conditions other than the normal one?
What went wrong in an existing, hydraulically limited system?
Discovering a pump that is 20 m short in a hydraulic tabulation costs a day; discovering it in start-up costs a shutdown.
2. The general procedure
Gather the heat and material balance for every stream in the circuit.
Draw a hydraulic flow diagram (HFD): a simplified P&ID showing only what carries pressure drop: line numbers, sizes, equipment, elevations, control valves, orifices, pumps.
Identify the fixed-pressure points: usually vessels held by a pressure controller, relief set pressures, or atmospheric tanks.
Define the hydraulic circuits between pairs of fixed-pressure points.
For each line, set the size, the pressure drop per 100 m and the equivalent length (Part 2).
Fix the equipment elevations (next section) and compute static head changes.
Assign equipment pressure drops: exchangers, heaters, filters, orifices, control valves.
Establish the pump differential and control-valve drop for the normal case.
Pro-rate to the design and turndown cases and check the control valve at each.
Tabulate everything line by line, with pressures at each node for each case, so any reviewer can follow the profile from one end to the other. Working backwards from the downstream fixed point to the control valve, then to the pump discharge, is the usual approach.
3. Setting equipment elevations
Elevation is a hydraulic decision, not just a layout one.
Column elevation is set by the largest of
Bottoms pump NPSH. The column bottom must sit high enough above the pump for NPSHa to exceed NPSHr plus margin (below).
Thermosiphon reboiler head, if used (see the heat-exchanger series).
Mechanical clearance under the skirt for piping, valves, instrument connections, and pump access.
Receiver elevation is set by
Overhead pump NPSH (the same argument; lower density needs a higher elevation for the same head).
Mechanical clearance, and if there is a water boot, the room below the drum for the boot and its level instruments.
Vessel minimum elevation from pump NPSH
Working from the vessel bottom tangent line down to the pump:
zmin=
All terms in metres of flowing liquid. The credits are: the pressure margin above vapour pressure (zero for a liquid at its bubble point, as in a reflux drum or column bottom) and the minimum controlled liquid level in the vessel above the tangent line. The debits are the pump's NPSHr, the pump centreline elevation above the baseline, the suction piping friction, and a contingency (more at the basic-engineering stage, when the contractor's detailed layout is unknown).
Estimate NPSHr from the pump curves for a single-stage centrifugal; use the rated capacity (normally 110 % of normal) and the pump speed. Half-speed (1450 rpm) pumps have much lower NPSHr than 2900 rpm pumps, which is why they are used where NPSH is scarce. Try the calculation interactively in Part 7.
Thermosiphon reboiler hydraulics
The reboiler elevation is set by a pressure balance (static head vs friction, entrance and exit losses; see the heat-exchanger series). The entrance loss to the column is about 1.0v2/2g and the exit loss from the column about 0.5v2/2g, both on the two-phase density.
Minimum column elevation: mechanical
Beyond NPSH, columns need a minimum tangent-line height for: a skirt (at least about 75 mm / 3″ of working height), piping off the bottom nozzle (about 1.5 pipe diameters), insulation and a 150 mm clearance, and room under the vessel head, which is typically about one quarter of the vessel diameter for 2:1 elliptical heads.
4. Typical equipment pressure drops
Use these until vendor data exist; always replace them with the real values.
Equipment
Typical ΔP
Crude heater
~8.6 bar (125 psi)
Vacuum heater
~5.2 bar (75 psi)
Hydrotreating heater
1.4 – 4 bar
Reformer (per heater)
0.2 – 1.4 bar
Coker heater
~20 bar
Visbreaker heater
~17 bar
Hot-oil heater
1.4 – 2.8 bar
Fired reboiler
~3.4 bar
Receivers, separators
≈ 0
Fractionator trays
~0.01 bar per tray (≈ 0.15 psi)
Shell & tube exchanger, normal fluid
The heater figures in particular are preliminary and must be confirmed by the heater design.
5. How much pressure drop does a control valve need?
A control valve controls by creating pressure drop. If it gets too little, it is wide open at normal flow and can't respond when more flow is required. If it gets too much, you are wasting pump head. In a pumped circuit, at normal flow allow the greatest of:
25 psi (about 1.7 bar),
50 % of the circuit's frictional pressure drop, or
7 – 10 % of the pump differential.
These ensure good drop when the flow is turned up to 110–120 %. In addition, at the design (rated) flow, the valve should still have at least 10 psi (about 0.7 bar). For other valves, drop is whatever the available pressure between two fixed points allows. The valve also has to cover the rangeability from turndown to about 110 % of capacity and compensate for fouling and ageing of the system.
6. Pro-rating pressure drops with flow
Lines, exchangers, heaters, orifices and other velocity-related items have pressure drop proportional to the square of flow, if density and viscosity do not change much:
ΔP2=ΔP
(In laminar flow the exponent is closer to 1; for turbulent, with the friction factor's slow Re dependence, it is about 1.8–2.0.) Static head terms do not scale.
7. The pump curve in the analysis
For a centrifugal pump the head is not constant: it rises as flow falls. For basic-design work a generic head curve is enough, normalised to the rated point:
The pump is rated at about 110 % of normal flow (this is a typical convention; adjust for your own spec).
At normal flow (90.9 % of rated) the head is about 1.04 × rated head.
At turndown 60 % of normal (54.5 % of rated) the head is about 1.18 × rated head.
Assign the rated head so the valve still has 0.7 bar at rated flow, then solve forward to the valve at the other flows using the curve. Take the actual curve from the pump vendor as soon as it exists.
8. Watch the pressure profile move
The waterfall below follows the circuit from the source vessel through suction line, pump, discharge line, orifice, exchanger, control valve and downstream line to the destination. Drag the flow from turndown (60 %) up to turn-up (120 %): at low flow the pump's high head all lands on the control valve; at high flow the valve runs out of drop and the circuit can no longer deliver:
Animation – A hydraulic pressure profile, and why the control valve absorbs the difference
Case: Turndown
50 % flow
Pump differential
14.63 bar
Control valve ΔP
5.91 bar
Valve share of friction
815 %
The valve has enough drop to control at this flow. The rule for normal flow is the greatest of 1.7 bar (25 psi), 50 % of the circuit friction and 10 % of the pump differential; the pump is then sized so the valve still has 0.7 bar (10 psi) at 110 % flow. Here the valve takes 1.84 bar at normal flow.
Friction grows with the square of flow, but a centrifugal pump delivers more head at low flow. The control valve sits in the gap. Slide the flow from turndown to turn-up and watch the valve drop swell, then vanish: size it for the whole range, not just the normal case.
That tension is the whole story of hydraulics. Choose the pump head to give the valve enough drop at the highest flow you must reach, and give the valve enough rangeability to throttle that surplus away at the lowest.
9. A worked tabulation: the layout
A hydraulic tabulation (normal / design / turndown) for an overhead liquid circuit usually has these rows, from the fixed pressure at the start to the fixed pressure at the end:
Row
Normal (100 %)
Design (110 %)
Turndown (60 %)
Pressure controller set point
P₀
P₀
P₀
Air condenser
ΔP
1.21 ΔP
0.36 ΔP
Condenser outlet line
line ΔP
×1.21
×0.36
Trim condenser
ΔP
×1.21
×0.36
Static head from vessel level
+ ρ g Δz
same
same
Receiver
—
—
Solve normal first: working from the destination back to the valve, assign the valve its drop by the rule above, continue to the pump discharge, and compute the pump differential. Then read the pump head at the other two flows from the curve and solve forward to the valve to find its drop.
10. Common findings in a hydraulic review
A control valve with less than 0.7 bar at design flow: the loop will saturate.
A pump with insufficient head at turn-up.
A column bottom too low for the pump NPSH.
Equipment design pressure that does not cover the highest hydraulic pressure (shut-in pump head plus suction pressure).
Line sizes that satisfy the criteria individually but give a pump differential that is uneconomic.
Summary
Build the profile between fixed pressure points, for normal, design and turndown cases.
Elevation is a hydraulic variable: NPSH and thermosiphon head set it.
Control valve: greatest of 1.7 bar, 50 % of friction, 7–10 % of pump ΔP, and still ≥ 0.7 bar at design flow.
Friction scales as flow squared; static head doesn't.
Part 7 goes inside the pump: curves, NPSH, cavitation and how to control flow efficiently.
NPSH
R
+
zpumpCL+
hf,suction−
(ρgPsys−Pvap)−
hliq,min+
contingency
≥ 0.35 bar per shell (5 psi), tube side about 0.35 bar more