Process Hydraulics, Part 5: Two-Phase Flow, Flow Regimes, Pressure Drop and Avoiding Slug Flow
Why two-phase lines are the hardest to size, horizontal and vertical flow patterns, the Baker map and superficial velocities, Lockhart–Martinelli pressure drop, erosional velocity (API RP 14E), and the design rules that keep slugs out of your piping. An interactive regime map with live pipe animation.
SM
Sumit Mathur
19 min read
When liquid and vapour share a pipe, the physics gets difficult. The two phases move at different speeds, the interface between them is rough and unsteady, and the pattern of flow, not just the flow rates, decides the pressure drop and the mechanical loads. Two-phase lines are everywhere in a plant: the outlet of a pressure-relief valve, reboiler return piping, steam-trap discharges, the line downstream of a control valve that flashes, and the feed to a column.
This is Part 5 of 10. Part 4 covered single-phase gas.
Pressure drop is underestimated if you size on the liquid alone or the gas alone: the combined effect is much larger than either, because the vapour squeezes the liquid into a smaller area and the rough interface adds drag. Higher-than-expected ΔP reduces plant capacity.
Control is poor. A two-phase stream is hard to regulate smoothly through a control valve.
Mechanical loads are real. Unsteady regimes, above all slug flow, give severe vibration and large unbalanced forces on piping and structures.
The main parameters that decide the regime are the volumetric flows of each phase, their physical properties (density, viscosity, surface tension), the diameter, and the orientation: horizontal, vertical upward, vertical downward or inclined.
2. Superficial velocities
The simplest way to describe a two-phase flow is by each phase's superficial velocity: the velocity that phase would have if it flowed alone in the pipe.
jL=AQ
Almost every flow-pattern map and correlation is built on these, or on mass velocities.
3. Vertical flow patterns
In upward vertical flow, as gas flow rises (with liquid flow fixed), the pattern passes through:
Bubble flow: gas as small, dispersed bubbles in a continuous liquid. Smooth.
Slug flow: the bubbles coalesce into large bullet-shaped gas pockets (Taylor bubbles) almost filling the pipe, separated by liquid slugs. Undesirable because of unsteady pressure and inertial loads on supports.
Churn flow: chaotic, frothy transition. Unstable and hard to predict.
Annular flow: liquid on the wall as a film, gas in the core. Stable and efficient.
Wispy-annular: annular with liquid also carried as clouds of droplets in the core.
Mist (dispersed) flow: all the liquid is droplets carried by the gas. Behaves like a compressible gas.
In vertical downflow the liquid tends to fall and the gas tends to rise, which reverses some of the logic; downflow is less common and benefits from flooding checks.
4. Horizontal flow patterns
Gravity separates the phases, so the patterns differ:
Pattern
Description
Comment
Bubble or froth
Gas bubbles dispersed in the liquid, riding the top
Acceptable
Plug
Plugs of liquid followed by plugs of gas
Intermittent loads
Stratified
Smooth layers, liquid below
Fine if the line stays level
Wave
Waves on the liquid surface
Can grow into slugs
Slug
Waves that touch the top of the pipe and rush forward as slugs
Avoid
Annular
Film on the wall, gas core
Good
The unit pressure drop differs a great deal between patterns, and many intermittent patterns lie between these classes.
5. See it, and measure it
Set the liquid and gas superficial velocities. The pipe shows what the flow pattern looks like, the map places your operating point among the regimes, and the readout gives the Lockhart–Martinelli two-phase pressure drop and the erosional-velocity check. Switch between vertical and horizontal to see why the same flows give different patterns:
Interactive – Two-phase flow: regime, pressure drop and erosion limit
Churn flow
Chaotic, unstable transition. Unsteady and hard to predict; avoid sizing here.
Lockhart–Martinelli X
0.84
Multiplier φL²
26.4
Friction ΔP
0.19 bar/100 m
Vmix / V erosional
3.6 / 12.4 m/s
Friction only; add the static head of vertical legs separately. Erosional velocity from the API RP 14E form Ve = C/√ρm with C = 100 (US units, continuous clean service).
Set the liquid and gas superficial velocities (the velocity each phase would have if it flowed alone). The pipe shows the flow pattern, the map locates it, and the Lockhart–Martinelli multiplier turns the single-phase liquid drop into a two-phase drop. Map boundaries are indicative, not a design chart.
(The map boundaries in the widget are indicative; real design uses the published maps such as Baker or Taitel–Dukler and vendor/simulator software.)
6. The classic pressure-drop procedure
The textbook design method (Lockhart–Martinelli, often via the Baker map) calculates each phase as if it flowed alone, then correlates the two-phase result to them:
Fictitious all-liquid ΔP (ΔPL∗): the whole mass flow treated as liquid at the liquid properties, in the real pipe.
Fictitious all-gas ΔP (ΔPG∗): the whole mass flow as gas at the gas properties.
Form the ratio and the Martinelli parameter:
X2=ΔPGΔP
where ΔPL and ΔPG are the single-phase drops with each phase flowing alone at its own flow. (Some versions use the liquid volume fraction instead; the charts in older handbooks do.)
Read or compute the two-phase multiplierϕL2. For turbulent–turbulent flow the Chisholm form is
ϕL2=1+XC
Two-phase ΔP: ΔPTP=ϕL2ΔP.
For wave flow a special friction factor is used (Huntington's method); for dispersed flow the Lockhart–Martinelli chart gives ϕG. For horizontal lines with rises, add the static head of the liquid in the vertical sections, using a liquid-head factor that depends on gas velocity.
Honest limits
These correlations are uncertain by 30 % or more. Good practice is to compute the pressure drop for the adjacent flow patterns too and apply a generous margin. The method assumes: isothermal flow, both phases turbulent, and pressure loss below about 10 % of the absolute upstream pressure. If the loss is higher, split the line into sections and sum them.
7. Erosional velocity (API RP 14E)
The mixture must not move faster than the erosional velocity:
Ve=
In SI this is Ve≈122/ρm m/s (for C=100, ρm in kg/m³). The mixture density ρm is the no-slip density at flowing conditions. Solids or corrosive fluids need a much lower C (as low as 50–75). Noise is the second sizing criterion in two-phase lines; keep the flow out of the range where noise and vibration become unacceptable.
8. Vertical flow: a quick slug check
A rough, widely used test: annular or mist flow is usually assured in a vertical riser if the mean two-phase velocity exceeds
vmin≈ρ
Example. 500 gpm of liquid (SG 0.75) plus 40,000 lb/h of vapour in a 10″ Schedule 80 riser. Mixture density 5.7 lb/ft³ (91 kg/m³), so vmin≈25 ft/s (7.7 m/s). Actual velocity: about 22 ft/s, which is just below the threshold: close to slug flow, so go to a flow-regime map to be sure, and probably reduce the line size.
9. How to avoid slug flow
Slug flow is the regime to design out. Tools:
Use a smaller line (higher velocity) so the flow moves up into annular or dispersed flow.
For a long vertical run, split it: use a smaller diameter at grade (where the velocity is lowest) and a larger one higher up as the gas expands.
Elevate the control valve on a column inlet so the two-phase flow produced by flashing has the shortest possible run.
Use parallel smaller lines at low flow.
Keep geometry simple: avoid low points that collect liquid, avoid dead legs, and use gravity flow where possible.
If you cannot design around it, prepare for it: brace and support the piping for the slug forces, and check with a dynamic analysis.
Dispersed flow, being nearly homogeneous, makes the mixture behave like a compressible fluid and is acceptable; all other regimes except slug and churn are generally acceptable.
10. Where you meet two-phase lines in practice
Control valve outlets that flash: put the valve next to the receiving vessel and size the downstream line for two-phase flow.
Thermosiphon reboiler return lines: stay in froth or annular flow to avoid slug-induced vibration (see the heat-exchanger series, Part 6 and 7).
Relief valve discharge headers: check erosional velocity, noise and back pressure.
Steam condensate with flash steam after traps.
Column feed lines with partial vaporisation.
Summary
Describe flows by superficial velocities, and find the regime before trusting a pressure-drop correlation.
Avoid slug and churn flow; annular and dispersed flow are the target.
ΔPTP=ϕL2ΔP, with uncertainty: compute neighbouring regimes and add margin.
Respect erosional velocity, keep liquid at the lowest pipe points drained, and support for slugs if you can't avoid them.
Part 6 assembles all this into the hydraulic calculation of a whole plant circuit.