Process Hydraulics, Part 4: Gas, Vapour and Steam Lines, Compressible Flow and Sonic Velocity
Why gas lines are different, sonic (critical) velocity and choking, the 10 % / 40 % rule for density change, isothermal flow equations, steam and vapour velocity guidelines by pressure and size, compressor and vacuum lines. An animated gas-line simulator with Mach number.
SM
Sumit Mathur
16 min read
A liquid is practically incompressible: its density is the same at the start and end of the pipe. A gas isn't. As pressure drops along a gas line the gas expands, its density falls, and since mass flow is constant, its velocity must rise. A gas line therefore accelerates toward its end, and there is a hard ceiling: the speed of sound.
Density changes along the line, so velocity and pressure drop per metre are not constant; pressure falls faster toward the downstream end.
Velocity limits come from noise, erosion (if any liquid or solids are present), vibration and the proximity of sonic flow.
Pressure drop matters twice: the energy to compress the gas, and in vacuum or low-pressure service the available driving force is tiny, so a few millibar can be a large fraction of the total.
Required properties: molecular weight, temperature, pressure, compressibility, viscosity, and k=Cp/Cv.
For quick work in the process-design phase, a gas line is sized exactly like a liquid line, using the gas density at the average pressure, as long as the pressure drop is small. How small? That is the next rule.
2. The 10 % and 40 % rule
The specific volume (or density) changes with the pressure drop, so check the total line ΔP as a fraction of the upstream absolute pressure:
Total ΔP / upstream absolute P
How to calculate
< 10 %
One calculation, using either the upstream or the downstream specific volume
10 – 40 %
Use the average specific volume
> 40 %
Divide the line into sections and calculate each with its own specific volume (or use the full compressible equation)
Slide the inlet pressure down or the length up in the simulator below until the line passes 40 % and the pressure curve visibly bends:
Animation – Pressure and velocity along a gas line
Outlet pressure
7.82 bara
ΔP / inlet P
2 %
Velocity in → out
13 → 13 m/s
Max Mach
0.03
Under 10 %: one calculation with inlet or outlet density is fine.
As gas expands along the pipe its density falls, so its velocity must rise: the line accelerates toward the sonic limit. This isothermal marching calculation shows the pressure falling faster toward the end, and the point where a line chokes.
3. Isothermal compressible flow
For a long gas line the flowing gas stays close to ambient temperature, so the isothermal model is a good approximation. For mass velocity G=m˙/A (kg/m²·s), the momentum balance is
−dP(1−MP2
Integrate along the pipe (the widget above marches this equation in 240 steps). Three things to notice:
The bracket (1−MP2G2RT goes to zero when the gas velocity reaches . At that point becomes infinite: the flow is .
At small pressure drops the bracket is near 1 and the familiar Darcy form applies.
Because ρ∝P, pressure falls ever faster toward the end of the line.
(Real long lines in lagged service are closer to adiabatic, where the sonic limit is at kRT/M and the pressure drop for a given flow is a bit different; for hand design the isothermal result is a standard conservative estimate.)
4. Sonic (critical) velocity
A compressible fluid cannot move faster than the speed of sound in that fluid at flowing conditions:
vc=M
It rises with temperature and falls with molecular weight: hydrogen (M = 2) has a speed of sound near 1300 m/s at 300 K; a heavy hydrocarbon vapour (M = 80) near 190 m/s.
It is a flow-rate limit: if you ignore it, your equation will happily calculate a flow the pipe cannot carry.
It appears at line ends (outlet to atmosphere or a larger vessel), where there is a sudden area change, and in vacuum lines, relief and flare piping and high-ΔP systems.
For trouble-free operation, keep the maximum gas Mach number to roughly 0.5–0.8 of sonic in normal service (with process lines usually kept well below), and for relief and flare headers use project limits (commonly Mach 0.5 in headers). Noise rises steeply as Mach number approaches 1.
5. Velocity guidelines for vapours and steam
These are typical ranges, not absolutes; high-velocity ends of a range need acoustic checks, and erosive or wet service should use the low end.
Process vapours and gases
Service
NPS ≤ 6
NPS 8 – 12
NPS ≥ 14
Saturated vapour, 0–3.5 barg
9 – 35 m/s
15 – 38
18 – 44
Gas or superheated, 0–0.7 barg
15 – 43
27 – 58
34 – 76
Gas, 0.8 – 7 barg
12 – 35
23 – 50
29 – 69
Gas, 7 – 63 barg
9 – 26
18 – 46
26 – 50
Larger pipes tolerate higher velocities because the noise power and the support loads per metre are lower relative to the wall.
Steam
Steam header
Max velocity (typical)
ΔP
Low-pressure (≈ 1 – 4 barg)
~25 m/s
~0.05 – 0.2 bar/100 m
Medium-pressure (≈ 4 – 18 barg)
~25 m/s
~0.1 – 0.5
High-pressure (≥ 18 barg)
~30 m/s
~0.2 – 0.7
Steam lines also see condensate, which needs slope, drip legs and traps. For saturated steam, a moist, high-velocity stream erodes bends and valve seats, so watch the velocity and keep drains working.
Vacuum lines
In a vacuum line, the entire driving pressure may be a few millibar, so design on total pressure drop (a very small number) rather than velocity, and use large lines with long-radius bends. The sonic limit is often the real constraint at the ejector or vacuum-pump end.
6. Compressor suction and discharge
Suction lines are sized for very low ΔP (a few percent at most of the suction absolute pressure): every percent of lost pressure costs a percent of capacity and extra power at the compressor. Avoid pockets that collect liquid, and use a suction knockout drum (Part 10).
Discharge lines can tolerate more ΔP, but pulsation from reciprocating machines demands low velocity and dampeners, with piping designed to avoid acoustic resonance.
Follow the vendor's pulsation study and the project specification.
7. Method summary (hand calculation)
Get gas properties at the flowing conditions, and the mass flow.
Compute the sonic velocity; ensure the planned velocity is a safe fraction of it.
Assume a size; compute G, Re (gas viscosity ~0.01 cP), f.
Use the isothermal equation (or the 10 % / 40 % rule with average density).
Check outlet Mach number and the velocity range for the service and size.
Repeat with the next size if a limit is exceeded.
Summary
Gas flow accelerates down the line; pressure drop per metre rises toward the end.
Check ΔP as a percentage of upstream absolute pressure and use sections above 40 %.
Never let the line approach sonic velocity: it chokes, and noise, vibration and erosion rise first.
Steam and vapour velocity limits depend on pressure, size and wetness.
Part 5 combines liquid and gas in one pipe, where the flow pattern matters as much as the numbers.